IEC 62443 certification prepared on your own plant
IEC 62443 certification confirms that a site, development process, component or system meets the parts of the series it names. IEC 62443 is supported in Rizzqo. You record each production line with the systems behind it and rate each gap as a risk in euros.
foundational requirements behind every system and component requirement
security levels, SL 1 to SL 4, graded by the strength of the attacker
how long an ISASecure certificate for a site in operation runs


Which role certifies what
The series hands out its parts by role. Your role decides what a certificate can cover.
Operate and integrate
Parts 2-1, 2-4, 3-2 and 3-3
Plant operators run a security program and divide the plant into zones. Integrators and maintenance firms prove their own processes. A certificate here covers a site in operation or a provider's capability.
What can be certified
- A site with its program and providers (ISASecure ACSSA)
- A service provider's capability under part 2-4 (IECEE)
- A control system under part 3-3 (ISASecure SSA or IECEE)
Build
Parts 4-1 and 4-2
Makers of controllers, gateways, switches and industrial software certify how they develop and what they ship. The process falls under part 4-1, each component under part 4-2.
What can be certified
- A development organization (ISASecure SDLA or IECEE)
- A component at a capability level (ISASecure CSA): application, embedded, host or network device
- CSA also checks the 4-1 process; SDLA can run alongside
Who asks, and who certifies
The series is a voluntary standard. Customers make it binding through purchase terms and tenders.
Roles named in the series
Each role starts from its own parts.
- Plant operators (asset owners)
- System integrators
- Maintenance service providers
- Makers of controllers and gateways
- Industrial software vendors
Routes to a certificate
Three routes exist, each with its own rules.
- ISASecure, through ISO/IEC 17065 accredited bodies
- IECEE, inside its CB Scheme
- Certification bodies with their own schemes
What IEC 62443 requires, part by part
These are the parts a certificate names. Editions are as of November 2026, from the IEC overview of the series and its webstore.
Foundations and operation
Parts 1 and 2
TS 1-1
Concepts and models
Terms, the zone and conduit model and the seven foundational requirements. Every other part builds on them.
Part 2-1
Security program for asset owners
Policies and procedures for a control system in operation. Edition 2.0 of 2024 adds a maturity model for rating each requirement.
Part 2-4
Service providers
The security capabilities that integrators and maintenance firms offer the plant operator. Edition 2.0 dates from 2023.
Systems and components
Parts 3 and 4
Part 3-2
Risk assessment, zones and conduits
You split the system into zones and conduits and assess the risk of each. Each one gets a target security level (SL-T).
Part 3-3
System requirements
Technical requirements for the control system, grouped under the seven foundational requirements. They define its capability level (SL-C).
Part 4-1
Secure development lifecycle
Process rules for product makers, from secure design and testing to defect handling, patches and end of life.
Part 4-2
Component requirements
Technical requirements for one component, such as a controller or a switch. They set the component's capability level.
Requirements and levels
FR and SL
FR 1 to 7
Seven foundational requirements
Identification and authentication control, use control, system integrity, data confidentiality, restricted data flow, timely response to events and resource availability.
SL 1 to 4
Four security levels
The levels grade protection by how strong an attacker is. A zone's target holds one level per foundational requirement.
The stages to IEC 62443 certification
Each scheme sets its own rules. These stages follow the ISASecure programs; under IECEE, national certification bodies issue the certificate.
Step 1
Name the part, the object and the level
A site, a development process, a component and a system each have their own program. Settle which one your customer expects before you apply.
Step 2
Apply and close the gaps
ISASecure bodies are accredited to ISO/IEC 17065. For a site, the body checks eligibility and can run a gap analysis first.
Step 3
The formal evaluation
A component is checked on its 4-1 process, its development artifacts, its security functions and in vulnerability tests. A site is checked against parts 2-1, 2-4, 3-2 and 3-3.
Step 4
Certificate and report
A site receives a certificate and a certification report. A component certificate states its type and capability level, such as level 3 for a software application.
Year 3
Surveillance and renewal
Periodic surveillance keeps an ACSSA site certificate valid until it expires. Recertification extends it past that date.
Planning an IEC 62443 audit?
In a demo we record one of your lines or products with you. You see where each requirement and each piece of evidence sits.
How Rizzqo models IEC 62443 on your plant
IEC 62443 is supported in Rizzqo. You start from the production process and record the systems it runs on in your asset inventory. Each gap then sits on a real asset.

One answer for several frameworks
A requirement can be linked to controls of several frameworks, such as ISO 27001 and the CRA. One finalized answer and its evidence then count for each. More than 25 frameworks are supported in Rizzqo, among them IEC 81001-5-1 and ISO/SAE 21434.
Related frameworks
From an IEC 62443 gap to a risk in euros
A dairy finds shared logins on the remote maintenance access to its filling line.
The figures are invented for illustration.
- 1.A dairy runs a yogurt filling line. The machine builder services it through a remote maintenance service.
- 2.The line is a process rated high for availability. Its controller, the production network and the remote maintenance service are its supporting assets.
- 3.A requirement on authenticated remote access attaches to the maintenance service. The service's assigned owner marks it "not fulfilled" and finalizes the answer: the builder's technicians share one login.
- 4.Without controls, a line stop is 40% likely and costs €450,000 in lost batches. That is €180,000 inherent risk.
- 5.A firewall rule and session logging already in place cut the likelihood to 20%. Current risk is €90,000.
- 6.A task, "personal logins with MFA for every technician", plans a cut to 5%. Planned residual risk: €22,500. Current risk stays at €90,000 until the task is done.
Worked example
IEC 62443: the gap in euros
- Asset
- Remote maintenance service for the filling line
- Gap
- The machine builder's technicians share one login
Inherent risk
Current risk, shared login
Residual risk, personal logins planned
Price a gap on one of your lines
Bring one production line. We work out with you what a stop costs today and what remains once the task is planned.
Read more on IEC 62443
IEC 62443 certification questions, answered
How long is an IEC 62443 certificate valid?
That depends on the scheme and the object. ISASecure grants a site (ACSSA) certificate for three years, kept up by periodic surveillance. A certificate shows the state at the time of the audit. ISASecure expects suppliers to keep patching and answering new vulnerabilities after it.
Which IEC 62443 certificate should we ask a supplier for?
Name the scheme, the part, the object and the level. A component certificate under part 4-2 should state the component type and its capability level. Compare that level with the target your part 3-2 risk assessment set for the zone. ISASecure also advises asking what was left out of the scope.
Will IEC 62443 become a harmonized standard under the CRA?
Parts of it are being adapted for that role. The DKE status list of October 2026 names amendments to parts 3-3, 4-1 and 4-2. It also lists the EN 50770 security profiles for products such as VPNs and firewalls, based on EN IEC 62443. Under Article 27(1) of the Cyber Resilience Act, presumption of conformity needs a harmonized standard cited in the Official Journal. The CRA's product requirements apply from December 11, 2027.
Is IEC 62443 certification required by law in Germany?
Not by name. The BSI Act (BSIG), Germany's NIS2 law, never mentions the series. Its § 30(2) covers particularly important and important entities. Their measures should follow the state of the art and heed relevant standards. Telecom providers, some energy operators and DORA financial entities are exempt under § 28(5) and (6) BSIG. A customer can still demand the certificate.
What should IEC 62443 software do?
It should show which systems run each line. It should show who answered each requirement and with what evidence, such as a component certificate under part 4-2. It should also price open gaps, so you know what to fix first before the audit. Rizzqo models the line and its systems and computes each risk in euros.

About the author
Muhammad Haseeb
Co-Founder & CTO
15 years of experience building software systems, responsible for all technical aspects of Rizzqo.
LinkedInReviewed by Masar Hetemi, Co-Founder & CEO. 15 years of experience in compliance, responsible for governance, risk and compliance (GRC) at Rizzqo.
See IEC 62443 on your own line
In the demo, we map one production line with its controllers, network and maintenance access. Then we rate one of its open gaps in euros.
- More than 25 frameworks supported
- A euro figure on every gap
- Hosted in your country